The SBSA UART has a fixed baud rate and flow control setting, which cannot be changed or queried by software. Add a vendor specific property to always return fixed values when trying to read the console options. Signed-off-by: Andre Przywara <andre.przywara@xxxxxxx> --- drivers/tty/serial/amba-pl011.c | 6 ++++++ 1 file changed, 6 insertions(+) diff --git a/drivers/tty/serial/amba-pl011.c b/drivers/tty/serial/amba-pl011.c index 70af210..12f1a5f 100644 --- a/drivers/tty/serial/amba-pl011.c +++ b/drivers/tty/serial/amba-pl011.c @@ -79,6 +79,7 @@ struct vendor_data { bool dma_threshold; bool cts_event_workaround; bool always_enabled; + char *fixed_options; unsigned int (*get_fifosize)(struct amba_device *dev); }; @@ -96,6 +97,7 @@ static struct vendor_data vendor_arm = { .dma_threshold = false, .cts_event_workaround = false, .always_enabled = false, + .fixed_options = NULL, .get_fifosize = get_fifosize_arm, }; @@ -112,6 +114,7 @@ static struct vendor_data vendor_st = { .dma_threshold = true, .cts_event_workaround = true, .always_enabled = false, + .fixed_options = NULL, .get_fifosize = get_fifosize_st, }; @@ -2062,6 +2065,9 @@ static int __init pl011_console_setup(struct console *co, char *options) uap->port.uartclk = clk_get_rate(uap->clk); + if (!options && uap->vendor->fixed_options) + options = uap->vendor->fixed_options; + if (options) uart_parse_options(options, &baud, &parity, &bits, &flow); else -- 1.7.9.5 -- To unsubscribe from this list: send the line "unsubscribe linux-serial" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html