Getting "Wrong diagnostic page; asked for 7 got 0" error message on HBA's virtual SES device

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi,

Our LSI(Broadcom) SAS3.5 HBA device's support virtual SES device.

Whenever we load the mpt3sas driver then we are observing below error message,

"Wrong diagnostic page; asked for 7 got 0"

Our virtual SES device doesn't support Diagnostic page 7, it supports
only below diagnostic pages,

• 00h List of Supported Diagnostic Pages
• 01h SES Configuration Diagnostic Page
• 02h SES Enclosure Control/Enclosure Status Diagnostic Page
• 0Ah SES Additional Element Status Diagnostic Page

Page Code 07 is Element Descriptor Diagnostic Page
Per SES3 spec (see table 10) this page is optional and not supported
by our internal VSES.

But 'ses' kernel module is issuing a RECEIVE_DIAGNOSTIC command for
diagnostic page 7 without checking whether target device supports this
page or not (i.e. without looking into 00h page) as shown below,

result = ses_recv_diag(sdev, 7, hdr_buf, INIT_ALLOC_SIZE);
        if (result)
                goto simple_populate;

As the virtual SES devices doesn't support this page 7, so it has
failed this RECEIVE_DIAGNOSTIC command with illegal request sense key
as shown below,

ses 11:0:0:0: tag#0 Send: scmd 0xffff883fee898000
ses 11:0:0:0: tag#0 CDB: Receive Diagnostic 1c 01 07 00 20 00
ses 11:0:0:0: tag#0 CDB: Receive Diagnostic 1c 01 07 00 20 00
mpt3sas_cm1:    sas_address(0x510600b012345600), phy(16)
mpt3sas_cm1:    enclosure_logical_id(0x500605b012345600),slot(16)
mpt3sas_cm1:    enclosure level(0x0000), connector name(     )
mpt3sas_cm1:    handle(0x0011), ioc_status(success)(0x0000), smid(1)
mpt3sas_cm1:    request_len(32), underflow(0), resid(32)
mpt3sas_cm1:    tag(0), transfer_count(0), sc->result(0x00000002)
mpt3sas_cm1:    scsi_status(check condition)(0x02),
scsi_state(autosense valid )(0x01)
mpt3sas_cm1:    [sense_key,asc,ascq]: [0x05,0x26,0x00], count(18)
mpt3sas_cm1: log_info(0x31200205): originator(PL), code(0x20), sub_code(0x0205)
ses 11:0:0:0: tag#0 Done: SUCCESS Result: hostbyte=DID_TARGET_FAILURE
driverbyte=DRIVER_OK
ses 11:0:0:0: tag#0 CDB: Receive Diagnostic 1c 01 07 00 20 00
ses 11:0:0:0: tag#0 Sense Key : Illegal Request [current]
ses 11:0:0:0: tag#0 Add. Sense: Invalid field in parameter list
ses 11:0:0:0: tag#0 scsi host busy 1 failed 0
ses 11:0:0:0: Notifying upper driver of completion (result 8100002)
ses 11:0:0:0: tag#0 0 sectors total, 32 bytes done.
ses 11:0:0:0: Wrong diagnostic page; asked for 7 got 0

As the command is failed with illegal request sense key, so the buffer
used In function 'ses_recv_diag' will be not updated and so it will
have all zero's. so the page_code will be zero and we observe below
wrong error message even though vSES device has failed the command
with illegal request error message and it has not returned any wrong
diagnostic page.

sdev_printk(KERN_ERR, sdev,
                    "Wrong diagnostic page; asked for %d got %u\n",
                    page_code, recv_page_code);

Thanks,
Sreekanth




[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[Index of Archives]     [SCSI Target Devel]     [Linux SCSI Target Infrastructure]     [Kernel Newbies]     [IDE]     [Security]     [Git]     [Netfilter]     [Bugtraq]     [Yosemite News]     [MIPS Linux]     [ARM Linux]     [Linux Security]     [Linux RAID]     [Linux ATA RAID]     [Linux IIO]     [Samba]     [Device Mapper]