Re: Getting "Wrong diagnostic page; asked for 7 got 0" error message on HBA's virtual SES device

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi,

Any Update?

Thanks,
Sreekanth

On Mon, Mar 13, 2017 at 12:13 PM, Sreekanth Reddy
<sreekanth.reddy@xxxxxxxxxxxx> wrote:
> Hi,
>
> Our LSI(Broadcom) SAS3.5 HBA device's support virtual SES device.
>
> Whenever we load the mpt3sas driver then we are observing below error message,
>
> "Wrong diagnostic page; asked for 7 got 0"
>
> Our virtual SES device doesn't support Diagnostic page 7, it supports
> only below diagnostic pages,
>
> • 00h List of Supported Diagnostic Pages
> • 01h SES Configuration Diagnostic Page
> • 02h SES Enclosure Control/Enclosure Status Diagnostic Page
> • 0Ah SES Additional Element Status Diagnostic Page
>
> Page Code 07 is Element Descriptor Diagnostic Page
> Per SES3 spec (see table 10) this page is optional and not supported
> by our internal VSES.
>
> But 'ses' kernel module is issuing a RECEIVE_DIAGNOSTIC command for
> diagnostic page 7 without checking whether target device supports this
> page or not (i.e. without looking into 00h page) as shown below,
>
> result = ses_recv_diag(sdev, 7, hdr_buf, INIT_ALLOC_SIZE);
>         if (result)
>                 goto simple_populate;
>
> As the virtual SES devices doesn't support this page 7, so it has
> failed this RECEIVE_DIAGNOSTIC command with illegal request sense key
> as shown below,
>
> ses 11:0:0:0: tag#0 Send: scmd 0xffff883fee898000
> ses 11:0:0:0: tag#0 CDB: Receive Diagnostic 1c 01 07 00 20 00
> ses 11:0:0:0: tag#0 CDB: Receive Diagnostic 1c 01 07 00 20 00
> mpt3sas_cm1:    sas_address(0x510600b012345600), phy(16)
> mpt3sas_cm1:    enclosure_logical_id(0x500605b012345600),slot(16)
> mpt3sas_cm1:    enclosure level(0x0000), connector name(     )
> mpt3sas_cm1:    handle(0x0011), ioc_status(success)(0x0000), smid(1)
> mpt3sas_cm1:    request_len(32), underflow(0), resid(32)
> mpt3sas_cm1:    tag(0), transfer_count(0), sc->result(0x00000002)
> mpt3sas_cm1:    scsi_status(check condition)(0x02),
> scsi_state(autosense valid )(0x01)
> mpt3sas_cm1:    [sense_key,asc,ascq]: [0x05,0x26,0x00], count(18)
> mpt3sas_cm1: log_info(0x31200205): originator(PL), code(0x20), sub_code(0x0205)
> ses 11:0:0:0: tag#0 Done: SUCCESS Result: hostbyte=DID_TARGET_FAILURE
> driverbyte=DRIVER_OK
> ses 11:0:0:0: tag#0 CDB: Receive Diagnostic 1c 01 07 00 20 00
> ses 11:0:0:0: tag#0 Sense Key : Illegal Request [current]
> ses 11:0:0:0: tag#0 Add. Sense: Invalid field in parameter list
> ses 11:0:0:0: tag#0 scsi host busy 1 failed 0
> ses 11:0:0:0: Notifying upper driver of completion (result 8100002)
> ses 11:0:0:0: tag#0 0 sectors total, 32 bytes done.
> ses 11:0:0:0: Wrong diagnostic page; asked for 7 got 0
>
> As the command is failed with illegal request sense key, so the buffer
> used In function 'ses_recv_diag' will be not updated and so it will
> have all zero's. so the page_code will be zero and we observe below
> wrong error message even though vSES device has failed the command
> with illegal request error message and it has not returned any wrong
> diagnostic page.
>
> sdev_printk(KERN_ERR, sdev,
>                     "Wrong diagnostic page; asked for %d got %u\n",
>                     page_code, recv_page_code);
>
> Thanks,
> Sreekanth




[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[Index of Archives]     [SCSI Target Devel]     [Linux SCSI Target Infrastructure]     [Kernel Newbies]     [IDE]     [Security]     [Git]     [Netfilter]     [Bugtraq]     [Yosemite News]     [MIPS Linux]     [ARM Linux]     [Linux Security]     [Linux RAID]     [Linux ATA RAID]     [Linux IIO]     [Samba]     [Device Mapper]

  Powered by Linux