On Wed, 08 Mar 2023 17:38:22 -0600, Sam Protsenko wrote: > As described in the corresponding binding documentation for > "samsung,exynos850-pmu", the "clocks" property should be used for > specifying CLKOUT mux inputs. Therefore, the clock provided to exynos850 > pmu_system_controller is incorrect and should be removed. Instead of > making syscon regmap keep that clock running for PMU accesses, it should > be made always running in the clock driver, because the kernel is not > the only software accessing PMU registers on Exynos850 platform. > > [...] Applied, thanks! [7/7] arm64: dts: exynos: Remove clock from Exynos850 pmu_system_controller https://git.kernel.org/krzk/linux/c/858fd147234dbb66401bc102968a479f92e7ad43 Best regards, -- Krzysztof Kozlowski <krzysztof.kozlowski@xxxxxxxxxx>