On 09/03/2023 00:38, Sam Protsenko wrote: > As described in the corresponding binding documentation for > "samsung,exynos850-pmu", the "clocks" property should be used for > specifying CLKOUT mux inputs. Therefore, the clock provided to exynos850 > pmu_system_controller is incorrect and should be removed. Instead of > making syscon regmap keep that clock running for PMU accesses, it should > be made always running in the clock driver, because the kernel is not > the only software accessing PMU registers on Exynos850 platform. > > Signed-off-by: Sam Protsenko <semen.protsenko@xxxxxxxxxx> > --- > arch/arm64/boot/dts/exynos/exynos850.dtsi | 1 - > 1 file changed, 1 deletion(-) To avoid any bisectability issues, I will apply this in the next cycle. Best regards, Krzysztof