On 05/12/2021 16:32, David Virag wrote: > Just like on Exynos850, the clock controller driver is designed to have > separate instances for each particular CMU, so clock IDs start from 1 > for each CMU in this bindings header too. > > Signed-off-by: David Virag <virag.david003@xxxxxxxxx> > --- > include/dt-bindings/clock/exynos7885.h | 115 +++++++++++++++++++++++++ > 1 file changed, 115 insertions(+) > create mode 100644 include/dt-bindings/clock/exynos7885.h This should be patch 1. Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@xxxxxxxxxxxxx> Best regards, Krzysztof