Hi Krzysztof,

On 17 July 2018 at 17:58, Krzysztof Kozlowski <krzk@xxxxxxxxxx> wrote:
> On 17 July 2018 at 12:12, Anand Moon <linux.amoon@xxxxxxxxx> wrote:
>> e-fuse range min~max range is 16~76. if e-fuse value is out of
>
> s/e-fuse/Fuse/
> s/if/If/
>
> Can you share the sources confirming that fuse values are between 16 and 76?
>
Below is my patch :
https://github.com/hardkernel/linux/commit/52c4c9b295930bc53b215d38e274aeb0780917f1

e-Fuse range min/max values are from exynos5422 user manual.

Best Regards
-Anand
--
To unsubscribe from this list: send the line "unsubscribe linux-samsung-soc" in
the body of a message to majordomo@xxxxxxxxxxxxxxx