On 17 July 2018 at 12:12, Anand Moon <linux.amoon@xxxxxxxxx> wrote: > e-fuse range min~max range is 16~76. if e-fuse value is out of s/e-fuse/Fuse/ s/if/If/ Can you share the sources confirming that fuse values are between 16 and 76? Best regards, Krzysztof > this range, then thermal sensor may not sense thermal data properly. > > CC: Bartlomiej Zolnierkiewicz <b.zolnierkie@xxxxxxxxxxx> > Signed-off-by: Anand Moon <linux.amoon@xxxxxxxxx> > --- > drivers/thermal/samsung/exynos_tmu.c | 10 ++++++---- > 1 file changed, 6 insertions(+), 4 deletions(-) > > diff --git a/drivers/thermal/samsung/exynos_tmu.c b/drivers/thermal/samsung/exynos_tmu.c > index 4a2733c..6481d91 100644 > --- a/drivers/thermal/samsung/exynos_tmu.c > +++ b/drivers/thermal/samsung/exynos_tmu.c > @@ -940,11 +940,13 @@ static int exynos_map_dt_data(struct platform_device *pdev) > data->reference_voltage = 16; > data->efuse_value = 55; > if (data->soc != SOC_ARCH_EXYNOS5420 && > - data->soc != SOC_ARCH_EXYNOS5420_TRIMINFO) > + data->soc != SOC_ARCH_EXYNOS5420_TRIMINFO) { > + data->min_efuse_value = 16; > + data->max_efuse_value = 76; > + } else { > data->min_efuse_value = 40; > - else > - data->min_efuse_value = 0; > - data->max_efuse_value = 100; > + data->max_efuse_value = 100; > + } > break; > case SOC_ARCH_EXYNOS5433: > data->tmu_set_trip_temp = exynos5433_tmu_set_trip_temp; > -- > 2.7.4 > -- To unsubscribe from this list: send the line "unsubscribe linux-samsung-soc" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html