On Tue, Jun 15, 2021 at 11:53:37AM +0200, Geert Uytterhoeven wrote: > Hi Laurent, > > On Tue, Jun 15, 2021 at 11:49 AM Laurent Pinchart > <laurent.pinchart@xxxxxxxxxxxxxxxx> wrote: > > On Tue, Jun 15, 2021 at 10:58:57AM +0200, Geert Uytterhoeven wrote: > > > On Mon, Jun 14, 2021 at 2:26 PM Geert Uytterhoeven <geert@xxxxxxxxxxxxxx> wrote: > > > > On Fri, Jun 11, 2021 at 3:46 PM Biju Das <biju.das.jz@xxxxxxxxxxxxxx> wrote: > > > > > Add clock entries for USB{0,1}. > > > > > > > > > > Signed-off-by: Biju Das <biju.das.jz@xxxxxxxxxxxxxx> > > > > > Reviewed-by: Lad Prabhakar <prabhakar.mahadev-lad.rj@xxxxxxxxxxxxxx> > > > > > > > > Thanks for your patch! > > > > > > > > > --- a/drivers/clk/renesas/r9a07g044-cpg.c > > > > > +++ b/drivers/clk/renesas/r9a07g044-cpg.c > > > > > @@ -88,6 +88,12 @@ static struct rzg2l_mod_clk r9a07g044_mod_clks[] = { > > > > > DEF_MOD("dmac", R9A07G044_CLK_DMAC, > > > > > R9A07G044_CLK_P1, > > > > > 0x52c, (BIT(0) | BIT(1)), (BIT(0) | BIT(1))), > > > > > + DEF_MOD("usb0", R9A07G044_CLK_USB0, > > > > > + R9A07G044_CLK_P1, > > > > > + 0x578, (BIT(0) | BIT(2) | BIT(3)), (BIT(0) | BIT(2) | BIT(3))), > > > > > + DEF_MOD("usb1", R9A07G044_CLK_USB1, > > > > > + R9A07G044_CLK_P1, > > > > > + 0x578, (BIT(1) | BIT(3)), (BIT(1) | BIT(3))), > > > > > DEF_MOD("scif0", R9A07G044_CLK_SCIF0, > > > > > R9A07G044_CLK_P0, > > > > > 0x584, BIT(0), BIT(0)), > > > > > > > > While the above matches the datasheet, I see a problem with the > > > > implementation. As BIT(3) of the CPG_{CLKON,CLKMON,RST}_USB is shared by > > > > the two USB2.0 channels, disabling USB_PCLK or asserting USB_PRESETN > > > > will affect both channels. So it looks like you need special handling > > > > to make sure that doesn't happen while the other channel is in use. > > > > > > > > Or am I missing something? > > > > > > I'm getting the impression we do have to model the individual bits > > > as separate clocks (and resets). That would solve the problem with > > > the shared USB_PCLK, as the clock framework will take care of keeping > > > it enabled when at least one channel is in use. > > > > > > Besides USB, SDHI has 4 clock bits, which we definitely don't want > > > to control together, as the card detect clock must not be stopped > > > while suspended. > > > However, the exception to the rule is Ethernet: each channel has > > > 2 clocks, but only a single bit to control, so this needs a custom > > > single-gate-for-dual-clock driver. > > > > Does it ? Can't the same clock be referenced twice in DT ? > > Yes, you can reference the same clock twice. But what's the point? > If they're two different clocks, DT should reference two different > clocks. But the single bit should correspond to the ORed value of > the two clock enable states. > > Or do you mean something different? If the device has two clock inputs, I'd model the two clocks separately in the DT bindings. If those two clocks are gated by the same bit in an SoC, we have two options to model the integration: - Create a driver that registers different clocks with the same gating bit. We'll have two clocks to reference in DT. - Model both clocks as a single clock in the clock driver, and reference that clock twice in DT. This is simpler, but only works if the consumer doesn't need to query the clock rate. -- Regards, Laurent Pinchart