Hi Morimoto-san, On Thursday 03 March 2016 08:37:02 Kuninori Morimoto wrote: > Hi Laurent > > >>>> - s2d2 (for 200MHz) > >>>> - s2d1 (for 400MHz) > >>> > >>> Thank you for the information. Do you mean that different FCP instances > >>> use different clocks ? If so, could you tell us which clock is used by > >>> each instance in th H3 ES1 ? > >> > >> Sorry for my confusable mail. > >> All FCP on H3 ES1 is using above, > >> but, M3 or E3 will use different clock. > >> > >> Is this more clear ? > > > > Does it mean that every FCP instance uses both the S2D2 and the S2D1 > > clocks as functional clocks on H3 ES1 ? > > - s2d2 (200MHz) is for APB-IF, > - s2d1 (400MHz) is for AXI-IF, and internal > > Is this clear answer ? It is, thank you very much for putting up with my slow mind ;-) Geert, deciding what clock to use as a parent for the MSTP clock becomes interesting, As S2D2 clocks the control interface I propose picking it. This shows the limits of the MSTP clock model though, MSTP is really a module stop bit, not a clock. -- Regards, Laurent Pinchart