Hi Morimoto-sa, On Thursday 03 March 2016 07:19:20 Kuninori Morimoto wrote: > Hi Laurent > > >> It seems FCP clock is based on each SoC > >> In H3 ES1 case, it is using > >> > >> - s2d2 (for 200MHz) > >> - s2d1 (for 400MHz) > > > > Thank you for the information. Do you mean that different FCP instances > > use different clocks ? If so, could you tell us which clock is used by > > each instance in th H3 ES1 ? > > Sorry for my confusable mail. > All FCP on H3 ES1 is using above, > but, M3 or E3 will use different clock. > > Is this more clear ? Does it mean that every FCP instance uses both the S2D2 and the S2D1 clocks as functional clocks on H3 ES1 ? -- Regards, Laurent Pinchart