Hi Laurent > > It seems FCP clock is based on each SoC > > In H3 ES1 case, it is using > > - s2d2 (for 200MHz) > > - s2d1 (for 400MHz) > > Thank you for the information. Do you mean that different FCP instances use > different clocks ? If so, could you tell us which clock is used by each > instance in th H3 ES1 ? Sorry for my confusable mail. All FCP on H3 ES1 is using above, but, M3 or E3 will use different clock. Is this more clear ?