On Thu, 2012-01-12 at 11:28 +0200, Tomi Valkeinen wrote: > Hi, > > On Wed, 2012-01-11 at 15:15 +0000, Joe Woodward wrote: > > > > The pm_runtime_get_sync() call in dss_runtime_get() is returning a > > > negative value, could you print out that value too? > > > > > > If the call to pm_runtime_get_sync() fails, we bail out immediately. So > > > the LCD interface shouldn't have been enabled at all. I don't know why > > > we get sync lost errors. > > > > > > There is a possibility that the LCD interface wasn't switched off when > > > for some reason when we suspended, and switching on the clocks again > > > tries to start the transfer without DSS being configured correctly? > > I can reproduce this on my Overo. The problem goes away if I change > dss's and dispc'c pm_runtime_put() calls to pm_runtime_put_sync(). But > I'm not quite sure why. (I seem to have not waken up today...) I also forgot to mention that the fail happens in drivers/base/power/runtime.c:rpm_resume(), where the check "dev->power.disable_depth > 0" causes the function to return EACCES. I'm not sure what disable_depth > 0 means. Tomi