On Thu, 2012-01-12 at 11:28 +0200, Tomi Valkeinen wrote: > Hi, > > On Wed, 2012-01-11 at 15:15 +0000, Joe Woodward wrote: > > > > The pm_runtime_get_sync() call in dss_runtime_get() is returning a > > > negative value, could you print out that value too? > > > > > > If the call to pm_runtime_get_sync() fails, we bail out immediately. So > > > the LCD interface shouldn't have been enabled at all. I don't know why > > > we get sync lost errors. > > > > > > There is a possibility that the LCD interface wasn't switched off when > > > for some reason when we suspended, and switching on the clocks again > > > tries to start the transfer without DSS being configured correctly? > > I can reproduce this on my Overo. The problem goes away if I change > dss's and dispc'c pm_runtime_put() calls to pm_runtime_put_sync(). But > I'm not quite sure why. Oh, one more thing. I didn't get any sync losts, but I may just have been lucky. So it may or may not be a separate problem. Tomi
Attachment:
signature.asc
Description: This is a digitally signed message part