On Thu, 26 Mar 2009 12:45:18 -0400 Steven Toth (ST) wrote: ST> I too tend to have multiple remotes, I don't think it's that unusual for ST> long standing Hauppauge customers to have many boards with many types of ST> remotes. ST> ST> > It might be better to have an option to explicitly allow old Hauppauge ST> > remotes that send 0x00. ST> > ST> I could live with this. It relegates older remotes but those remotes ST> are no longer made. This feels like a good compromise. How about changing the parameter such that it is a filter mask? The default value of 0x0 would accept all remotes. For non-zero values, each bit set in the parameter would filter the device address corresponding to that bit, e.g. 0x1 would filter address 0x0, 0x80000000 would filter address 0x1f, etc. Cheers, - Udo