Re: [PATCH V7 6/6] backlight: qcom-wled: Add auto string detection logic

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 2019-10-17 16:59, Daniel Thompson wrote:
On Wed, Oct 16, 2019 at 03:43:46PM +0530, Kiran Gunda wrote:
The auto string detection algorithm checks if the current WLED
sink configuration is valid. It tries enabling every sink and
checks if the OVP fault is observed. Based on this information
it detects and enables the valid sink configuration.
Auto calibration will be triggered when the OVP fault interrupts
are seen frequently thereby it tries to fix the sink configuration.

The auto-detection also kicks in when the connected LED string
of the display-backlight malfunctions (because of damage) and
requires the damaged string to be turned off to prevent the
complete panel and/or board from being damaged.

Signed-off-by: Kiran Gunda <kgunda@xxxxxxxxxxxxxx>

It's a complex bit of code but I'm OK with it in principle. Everything
below is about small details and/or nitpicking.


+static void wled_ovp_work(struct work_struct *work)
+{
+	struct wled *wled = container_of(work,
+					 struct wled, ovp_work.work);
+	enable_irq(wled->ovp_irq);
+}
+

A bit of commenting about why we have to wait 10ms before enabling the
OVP interrupt would be appreciated.


Sure. Will add the comment in the next series.
+static irqreturn_t wled_ovp_irq_handler(int irq, void *_wled)
+{
+	struct wled *wled = _wled;
+	int rc;
+	u32 int_sts, fault_sts;
+
+	rc = regmap_read(wled->regmap,
+			 wled->ctrl_addr + WLED3_CTRL_REG_INT_RT_STS, &int_sts);
+	if (rc < 0) {
+		dev_err(wled->dev, "Error in reading WLED3_INT_RT_STS rc=%d\n",
+			rc);
+		return IRQ_HANDLED;
+	}
+
+	rc = regmap_read(wled->regmap, wled->ctrl_addr +
+			 WLED3_CTRL_REG_FAULT_STATUS, &fault_sts);
+	if (rc < 0) {
+		dev_err(wled->dev, "Error in reading WLED_FAULT_STATUS rc=%d\n",
+			rc);
+		return IRQ_HANDLED;
+	}
+
+	if (fault_sts &
+		(WLED3_CTRL_REG_OVP_FAULT_BIT | WLED3_CTRL_REG_ILIM_FAULT_BIT))
+ dev_dbg(wled->dev, "WLED OVP fault detected, int_sts=%x fault_sts= %x\n",
+			int_sts, fault_sts);
+
+	if (fault_sts & WLED3_CTRL_REG_OVP_FAULT_BIT) {
+		mutex_lock(&wled->lock);
+		disable_irq_nosync(wled->ovp_irq);

We're currently running the threaded ISR for this irq. Do we really need
to disable it?

We need to disable this IRQ, during the auto string detection logic. Because in the auto string detection we configure the current sinks one by one and check the status register for the OVPs and set the right string configuration. We enable it later after
the auto string detection is completed.
+
+		if (wled_auto_detection_required(wled))
+			wled_auto_string_detection(wled);
+
+		enable_irq(wled->ovp_irq);
+
+		mutex_unlock(&wled->lock);
+	}
+
+	return IRQ_HANDLED;
+}
+

Snip.


+static int wled_remove(struct platform_device *pdev)
+{
+	struct wled *wled = dev_get_drvdata(&pdev->dev);
+
+	cancel_delayed_work_sync(&wled->ovp_work);
+	mutex_destroy(&wled->lock);

Have the irq handlers been disabled at this point?

Ok.. may not be. I will disable the irq's here in next series.

Also, if you want to destroy the mutex shouldn't that code be
introduced in the same patch that introduces the mutex?
Ok.. I will move it to the same patch where the mutex introduced in next series.
+
+	return 0;
+}


Daniel.



[Index of Archives]     [Linux ARM Kernel]     [Linux ARM]     [Linux Omap]     [Fedora ARM]     [IETF Annouce]     [Security]     [Bugtraq]     [Linux OMAP]     [Linux MIPS]     [ECOS]     [Asterisk Internet PBX]     [Linux API]

  Powered by Linux