On Tue 2019-08-13 13:11:53, Dan Murphy wrote: > Add a property for each control bank to configure the > full scale current setting for the device. > > Signed-off-by: Dan Murphy <dmurphy@xxxxxx> Acked-by: Pavel Machek <pavel@xxxxxx> > @@ -62,6 +62,9 @@ Optional LED child properties: > - label : see Documentation/devicetree/bindings/leds/common.txt > - linux,default-trigger : > see Documentation/devicetree/bindings/leds/common.txt > + - led-max-microamp : Defines the full scale current value for each control > + bank. The range is from 5000uA-29800uA in increments > + of 800uA. > > Example: > led-controller@38 { > @@ -85,6 +88,7 @@ led-controller@38 { > reg = <0>; > led-sources = <2>; > ti,led-mode = <1>; > + led-max-microamp = <21800>; > label = ":backlight"; > linux,default-trigger = "backlight"; > }; -- (english) http://www.livejournal.com/~pavelmachek (cesky, pictures) http://atrey.karlin.mff.cuni.cz/~pavel/picture/horses/blog.html