[PATCH v2 0/3] iio: magnetometer: add support for the Allegro MicroSystems ALS31300 3-D Linear Hall Effect Sensor

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



The Allegro MicroSystems ALS31300 is a 3-D Linear Hall Effect Sensor
mainly used in 3D sensing applications for head-on motion.

The device is configured over I2C, and as part of the Sensor
data the temperature core is also provided.

While the device provides an IRQ gpio, it depends on a configuration
programmed into the internal EEPROM, thus only the default mode
is supported and buffered input via trigger is also supported
to allow streaming values with the same sensing timestamp.

The device can be configured with different sensitivities in factory,
but the sensitivity value used to calculate value into the Gauss
unit is not available from registers, thus the sensitivity is
provided by the compatible/device-id string which is based
on the part number as described in the datasheet page 2.
    
The datasheet is available on the product website at [1].

[1] https://www.allegromicro.com/en/products/sense/linear-and-angular-position/linear-position-sensor-ics/als31300

Signed-off-by: Neil Armstrong <neil.armstrong@xxxxxxxxxx>
---
Changes in v2:
- Add rob's Ack on patch 1
- Fix commit message layout on patches 2 & 3
- Use Datasheet tag on patch 2
- Fix bindings file name, add options interrupts, fix example node name & compatible
- Fix driver with Jonathan's advices:
  - Reword top file comments
  - Reduce VOLATILE defines
  - Move registers values next to register define and add an indent
  - Use sign_extend32() to X/Y/Z macro, dtop cast on temperature macro
  - Add als31300_variant_info to pass to i2c/of device_id
  - Move scan buffer to irq function
  - Use guard(mutex)
  - Return fractional for millicelcius
  - switch to aligned_s64
  - use index 4 for IIO_CHAN_SOFT_TIMESTAMP
  - Add usleep after switching to ACTIVE state to avoid hitting read errors after wake up
  - simplify suspend/resume functions by returning als31300_set_operating_mode()
- Link to v1: https://lore.kernel.org/r/20241007-topic-input-upstream-als31300-v1-0-2c240ea5cb77@xxxxxxxxxx

---
Neil Armstrong (3):
      dt-bindings: vendor-prefixes: Add Allegro MicroSystems, Inc
      dt-bindings: iio: magnetometer: document the Allegro MicroSystems ALS31300 3-D Linear Hall Effect Sensor
      iio: magnetometer: add Allegro MicroSystems ALS31300 3-D Linear Hall Effect driver

 .../iio/magnetometer/allegromicro,als31300.yaml    |  46 ++
 .../devicetree/bindings/vendor-prefixes.yaml       |   2 +
 drivers/iio/magnetometer/Kconfig                   |  13 +
 drivers/iio/magnetometer/Makefile                  |   1 +
 drivers/iio/magnetometer/als31300.c                | 495 +++++++++++++++++++++
 5 files changed, 557 insertions(+)
---
base-commit: 57573ace0c1b142433dfe3d63ebf375269c80fc1
change-id: 20241002-topic-input-upstream-als31300-ca7404eb4ab0

Best regards,
-- 
Neil Armstrong <neil.armstrong@xxxxxxxxxx>





[Index of Archives]     [Linux USB Devel]     [Video for Linux]     [Linux Audio Users]     [Yosemite News]     [Linux Input]     [Linux Kernel]     [Linux SCSI]     [X.org]

  Powered by Linux