On Wed, Aug 28, 2024 at 10:51:22PM +0200, Vasileios Amoiridis wrote: > The BM(P/E)28x devices have an option for soft reset which is also > recommended by the Bosch Sensortech BME2 Sensor API to be used before the > initial configuration of the device. ... > +static int bmp280_preinit(struct bmp280_data *data) > +{ With struct device *dev = data->dev; it will look better? > + unsigned int reg; > + int ret; > + ret = regmap_write(data->regmap, BMP280_REG_RESET, BMP280_RST_SOFT_CMD); > + if (ret) > + return dev_err_probe(data->dev, ret, > + "Failed to reset device.\n"); return dev_err_probe(dev, ret, "Failed to reset device.\n"); > + /* > + * According to the datasheet in Chapter 1: Specification, Table 2, > + * after resetting, the device uses the complete power-on sequence so > + * it needs to wait for the defined start-up time. > + */ > + fsleep(data->start_up_time); > + > + ret = regmap_read(data->regmap, BMP280_REG_STATUS, ®); > + if (ret) > + return dev_err_probe(data->dev, ret, > + "Failed to read status register.\n"); return dev_err_probe(dev, ret, "Failed to read status register.\n"); > + if (reg & BMP280_REG_STATUS_IM_UPDATE) > + return dev_err_probe(data->dev, -EIO, > + "Failed to copy NVM contents.\n"); return dev_err_probe(dev, -EIO, "Failed to copy NVM contents.\n"); > + return 0; > +} Yes, it's up to 84 characters long, but I think it improves readability. -- With Best Regards, Andy Shevchenko