Hello Lee, On Fri, Jun 14, 2024 at 10:31:24AM +0100, Lee Jones wrote: > On Fri, 14 Jun 2024, Uwe Kleine-König wrote: > > > These two defines have the same purpose and this change doesn't > > introduce any differences in drivers/counter/stm32-timer-cnt.o. > > > > The only difference between the two is that > > > > TIM_DIER_CC_IE(1) == TIM_DIER_CC2IE > > > > while > > > > TIM_DIER_CCxIE(1) == TIM_DIER_CC1IE > > > > . That makes it necessary to have an explicit "+ 1" in the user code, > > but IMHO this is a good thing as this is the code locatation that > > "knows" that for software channel 1 you have to use TIM_DIER_CC2IE > > (because software guys start counting at 0, while the relevant hardware > > designer started at 1). > > > > Signed-off-by: Uwe Kleine-König <u.kleine-koenig@xxxxxxxxxxxx> > > --- > > drivers/counter/stm32-timer-cnt.c | 4 ++-- > > The subject should be renamed. I guess you mean it should be something like: counter: stm32-timer-cnt: Drop TIM_DIER_CC_IE(x) in favour of TIM_DIER_CCxIE(x + 1) ? Best regards Uwe