On Thu, 6 Jun 2024 23:22:53 +0200 Vasileios Amoiridis <vassilisamir@xxxxxxxxx> wrote: > The IIO standard units are measured in kPa while the driver > is using hPa. > > Apart from checking the userspace value itself, it is mentioned also > in the Bosch API [1] that the pressure value is in Pascal. > > [1]: https://github.com/boschsensortec/BME68x_SensorAPI/blob/v4.4.8/bme68x_defs.h#L742 > Fixes: 1b3bd8592780 ("iio: chemical: Add support for Bosch BME680 sensor") > Signed-off-by: Vasileios Amoiridis <vassilisamir@xxxxxxxxx> Given we are early in the cycle I'm going to take the fixes via the fixes-togreg branch of iio.git. Thanks will slow down the rest a little but we still have time that that should not matter and we'll get these fixes into stable much sooner. Applied to the fixes-togreg branch of iio.git and marked for stable. Thanks, Jonathan > --- > drivers/iio/chemical/bme680_core.c | 2 +- > 1 file changed, 1 insertion(+), 1 deletion(-) > > diff --git a/drivers/iio/chemical/bme680_core.c b/drivers/iio/chemical/bme680_core.c > index ef5e0e46fd34..2c40c13fe97a 100644 > --- a/drivers/iio/chemical/bme680_core.c > +++ b/drivers/iio/chemical/bme680_core.c > @@ -678,7 +678,7 @@ static int bme680_read_press(struct bme680_data *data, > } > > *val = bme680_compensate_press(data, adc_press); > - *val2 = 100; > + *val2 = 1000; > return IIO_VAL_FRACTIONAL; > } > > > base-commit: b3019fcdeb286b2cfe45e44bccb44dbcd8ff66dd