There is no need to explicitly configure the gas measurement registers every time a gas measurement takes place. These are initial configurations which are written in the beginning and they are not changed throughout the lifetime of the driver. If in the future, the device starts to support multiple configuration profiles with variable heater duration and heater temperature, then they could become members of the ->read_avail(). Signed-off-by: Vasileios Amoiridis <vassilisamir@xxxxxxxxx> --- drivers/iio/chemical/bme680_core.c | 7 ------- 1 file changed, 7 deletions(-) diff --git a/drivers/iio/chemical/bme680_core.c b/drivers/iio/chemical/bme680_core.c index afaa43ec3241..a91b15626ec8 100644 --- a/drivers/iio/chemical/bme680_core.c +++ b/drivers/iio/chemical/bme680_core.c @@ -669,13 +669,6 @@ static int bme680_read_gas(struct bme680_data *data, u16 adc_gas_res, gas_regs_val; u8 gas_range; - /* Set heater settings */ - ret = bme680_gas_config(data); - if (ret < 0) { - dev_err(dev, "failed to set gas config\n"); - return ret; - } - /* set forced mode to trigger measurement */ ret = bme680_set_mode(data, true); if (ret < 0) -- 2.25.1