On Thu, 7 Dec 2023 14:41:50 +0100 Marek Vasut <marex@xxxxxxx> wrote: > Add comment about intensity scale being poorly defined and > having no proper units. > > Signed-off-by: Marek Vasut <marex@xxxxxxx> Applied. Thanks for cleaning this up. Jonathan > --- > Cc: Jonathan Cameron <jic23@xxxxxxxxxx> > Cc: Lars-Peter Clausen <lars@xxxxxxxxxx> > Cc: linux-iio@xxxxxxxxxxxxxxx > --- > Documentation/ABI/testing/sysfs-bus-iio | 4 +++- > 1 file changed, 3 insertions(+), 1 deletion(-) > > diff --git a/Documentation/ABI/testing/sysfs-bus-iio b/Documentation/ABI/testing/sysfs-bus-iio > index 0d3ec5fc45f2f..94b8d8461b7c7 100644 > --- a/Documentation/ABI/testing/sysfs-bus-iio > +++ b/Documentation/ABI/testing/sysfs-bus-iio > @@ -618,7 +618,9 @@ KernelVersion: 2.6.35 > Contact: linux-iio@xxxxxxxxxxxxxxx > Description: > If a discrete set of scale values is available, they > - are listed in this attribute. > + are listed in this attribute. Unlike illumination, > + multiplying intensity by intensity_scale does not > + yield value with any standardized unit. > > What: /sys/bus/iio/devices/iio:deviceX/out_voltageY_hardwaregain > What: /sys/bus/iio/devices/iio:deviceX/in_intensity_hardwaregain