Re: [PATCH 2/2] iio: accel: bma180: Add missing 500 Hz / 1000 Hz bandwidth

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Wed, May 26, 2021 at 11:44 AM Stephan Gerhold <stephan@xxxxxxxxxxx> wrote:

> According to the BMA253 datasheet [1] and BMA250 datasheet [2] BMA25x
> also supports a bandwidth of 500 Hz and 1000 Hz but this was not listed
> in the driver for some reason.
>
> Add it to the bw_table to make the driver match the datasheet.
>
> [1]: https://www.bosch-sensortec.com/media/boschsensortec/downloads/datasheets/bst-bma253-ds000.pdf
> [2]: https://datasheet.octopart.com/BMA250-Bosch-datasheet-15540103.pdf
>
> Cc: Peter Meerwald <pmeerw@xxxxxxxxxx>
> Cc: Linus Walleij <linus.walleij@xxxxxxxxxx>
> Signed-off-by: Stephan Gerhold <stephan@xxxxxxxxxxx>

Reviewed-by: Linus Walleij <linus.walleij@xxxxxxxxxx>

Yours,
Linus Walleij