qcom_vadc7_scale_hw_calib_die_temp() uses a table format different from the rest of volt/temp conversion functions in this file. Also the conversion functions results in non-monothonic values conversion, which seems wrong. Rewrite qcom_vadc7_scale_hw_calib_die_temp() to use qcom_vadc_map_voltage_temp() directly, like the rest of conversion functions do. Signed-off-by: Dmitry Baryshkov <dmitry.baryshkov@xxxxxxxxxx> --- drivers/iio/adc/qcom-vadc-common.c | 50 +++++++----------------- include/linux/iio/adc/qcom-vadc-common.h | 5 --- 2 files changed, 15 insertions(+), 40 deletions(-) diff --git a/drivers/iio/adc/qcom-vadc-common.c b/drivers/iio/adc/qcom-vadc-common.c index 45a38602f66a..0c705bb473fe 100644 --- a/drivers/iio/adc/qcom-vadc-common.c +++ b/drivers/iio/adc/qcom-vadc-common.c @@ -101,18 +101,18 @@ static const struct vadc_map_pt adcmap_100k_104ef_104fb_1875_vref[] = { }; static const struct vadc_map_pt adcmap7_die_temp[] = { - { 433700, 1967}, - { 473100, 1964}, - { 512400, 1957}, - { 551500, 1949}, - { 590500, 1940}, - { 629300, 1930}, - { 667900, 1921}, - { 706400, 1910}, - { 744600, 1896}, - { 782500, 1878}, - { 820100, 1859}, - { 857300, 0}, + { 857300, 160000 }, + { 820100, 140000 }, + { 782500, 120000 }, + { 744600, 100000 }, + { 706400, 80000 }, + { 667900, 60000 }, + { 629300, 40000 }, + { 590500, 20000 }, + { 551500, 0 }, + { 512400, -20000 }, + { 473100, -40000 }, + { 433700, -60000 }, }; /* @@ -585,33 +585,13 @@ static int qcom_vadc7_scale_hw_calib_die_temp( u16 adc_code, int *result_mdec) { - int voltage, vtemp0, temp, i; + int voltage; voltage = qcom_vadc_scale_code_voltage_factor(adc_code, prescale, data, 1); - if (adcmap7_die_temp[0].x > voltage) { - *result_mdec = DIE_TEMP_ADC7_SCALE_1; - return 0; - } - - if (adcmap7_die_temp[ARRAY_SIZE(adcmap7_die_temp) - 1].x <= voltage) { - *result_mdec = DIE_TEMP_ADC7_MAX; - return 0; - } - - for (i = 0; i < ARRAY_SIZE(adcmap7_die_temp); i++) - if (adcmap7_die_temp[i].x > voltage) - break; - - vtemp0 = adcmap7_die_temp[i - 1].x; - voltage = voltage - vtemp0; - temp = div64_s64(voltage * DIE_TEMP_ADC7_SCALE_FACTOR, - adcmap7_die_temp[i - 1].y); - temp += DIE_TEMP_ADC7_SCALE_1 + (DIE_TEMP_ADC7_SCALE_2 * (i - 1)); - *result_mdec = temp; - - return 0; + return qcom_vadc_map_voltage_temp(adcmap7_die_temp, ARRAY_SIZE(adcmap7_die_temp), + voltage, result_mdec); } static int qcom_vadc_scale_hw_smb_temp( diff --git a/include/linux/iio/adc/qcom-vadc-common.h b/include/linux/iio/adc/qcom-vadc-common.h index 1d337dd9e3dc..58216124d89d 100644 --- a/include/linux/iio/adc/qcom-vadc-common.h +++ b/include/linux/iio/adc/qcom-vadc-common.h @@ -54,11 +54,6 @@ #define R_PU_100K 100000 #define RATIO_MAX_ADC7 BIT(14) -#define DIE_TEMP_ADC7_SCALE_1 -60000 -#define DIE_TEMP_ADC7_SCALE_2 20000 -#define DIE_TEMP_ADC7_SCALE_FACTOR 1000 -#define DIE_TEMP_ADC7_MAX 160000 - /* * VADC_CALIB_ABSOLUTE: uses the 625mV and 1.25V as reference channels. * VADC_CALIB_RATIOMETRIC: uses the reference voltage (1.8V) and GND for -- 2.29.2