From: Philippe Schenker <philippe.schenker@xxxxxxxxxxx> In some cases, the wait_completion got interrupted. This caused the error-handling to mutex_unlock the function. The before turned on interrupt then got called anyway. In the ISR then completion() was called causing wrong adc-values returned in a following adc-readout. Reinitialise completion struct to make sure the counter is zero when beginning a new adc-conversion. Signed-off-by: Philippe Schenker <philippe.schenker@xxxxxxxxxxx> --- drivers/iio/adc/stmpe-adc.c | 4 ++++ 1 file changed, 4 insertions(+) diff --git a/drivers/iio/adc/stmpe-adc.c b/drivers/iio/adc/stmpe-adc.c index 9ec338ba3440..b3872eb37293 100644 --- a/drivers/iio/adc/stmpe-adc.c +++ b/drivers/iio/adc/stmpe-adc.c @@ -65,6 +65,8 @@ static int stmpe_read_voltage(struct stmpe_adc *info, mutex_lock(&info->lock); + reinit_completion(&info->completion); + info->channel = (u8)chan->channel; if (info->channel > STMPE_ADC_LAST_NR) { @@ -105,6 +107,8 @@ static int stmpe_read_temp(struct stmpe_adc *info, mutex_lock(&info->lock); + reinit_completion(&info->completion); + info->channel = (u8)chan->channel; if (info->channel != STMPE_TEMP_CHANNEL) { -- 2.21.0