When using the internal clock the device has an option in which the clock output is available on MCLK2 pin. This patch adds a dt binding for enabling this property. Signed-off-by: Mircea Caprioru <mircea.caprioru@xxxxxxxxxx> --- drivers/staging/iio/adc/ad7192.c | 9 ++++++++- 1 file changed, 8 insertions(+), 1 deletion(-) diff --git a/drivers/staging/iio/adc/ad7192.c b/drivers/staging/iio/adc/ad7192.c index 8a4e6ede42b3..a11c8a82bb7c 100644 --- a/drivers/staging/iio/adc/ad7192.c +++ b/drivers/staging/iio/adc/ad7192.c @@ -611,6 +611,10 @@ static const struct iio_chan_spec ad7193_channels[] = { static int ad7192_clock_select(struct spi_device *spi, struct ad7192_state *st) { int ret; + bool clock_out_en; + + clock_out_en = of_property_read_bool(spi->dev.of_node, + "adi,int-clock-output-enable"); st->clock_sel = AD7192_CLK_EXT_MCLK2; st->mclk = devm_clk_get(&spi->dev, "clk"); @@ -626,7 +630,10 @@ static int ad7192_clock_select(struct spi_device *spi, struct ad7192_state *st) return PTR_ERR(st->mclk); /* use internal clock */ - st->clock_sel = AD7192_CLK_INT; + if (!clock_out_en) + st->clock_sel = AD7192_CLK_INT; + else + st->clock_sel = AD7192_CLK_INT_CO; st->fclk = AD7192_INT_FREQ_MHZ; } } -- 2.17.1