On 2018/9/8 22:17, Jonathan Cameron wrote: > On Sat, 8 Sep 2018 17:59:13 +0530 > Himanshu Jha <himanshujha199640@xxxxxxxxx> wrote: > >> On Sat, Sep 08, 2018 at 06:57:36PM +0800, zhong jiang wrote: >>> The iterator in for_each_set_bit is never null, therefore, remove >>> the redundant conditional judgment. >>> >>> Signed-off-by: zhong jiang <zhongjiang@xxxxxxxxxx> >>> --- >>> drivers/iio/humidity/am2315.c | 3 +-- >>> 1 file changed, 1 insertion(+), 2 deletions(-) >>> >>> diff --git a/drivers/iio/humidity/am2315.c b/drivers/iio/humidity/am2315.c >>> index 7d8669d..dc12e37 100644 >>> --- a/drivers/iio/humidity/am2315.c >>> +++ b/drivers/iio/humidity/am2315.c >>> @@ -176,8 +176,7 @@ static irqreturn_t am2315_trigger_handler(int irq, void *p) >>> i = 0; >>> for_each_set_bit(bit, indio_dev->active_scan_mask, >>> indio_dev->masklength) { >>> - data->buffer[i] = (bit ? sensor_data.temp_data : >>> - sensor_data.hum_data); >>> + data->buffer[i] = sensor_data.temp_data; >> No, this seems wrong! >> >> We have buffer support to either take both readings(temp & humid) >> simultaneously, or only single channel using specified scan mask. > Key think is that bit most definitely can be 0 if the 0th bit is set. > This isn't a null check at all. > > I'm curious, was this a by inspection case or did some script throw > this one up? Hi, Jonathan bit is a iterator that find the non-zero bit in indio_dev->active_scan_mask. if all bit is zero , it should return the masklength. Yep. I find the issue with the help of Coccinelle. Thanks zhong jiang > Thanks, > > Jonathan > >> Patch title should be: >> >> "iio: humidity: am2315: .... .. " >> >> >> Thanks > > . >