Thanks for the fix. Agree with the whole series.
Thanks,
Srinivas
On 07/02/2014 11:44 PM, Sachin Kamat wrote:
IIO_CHAN_INFO_SAMP_FREQ and IIO_CHAN_INFO_HYSTERESIS cases ignored
the actual return values (which could be -EINVAL) and instead
returned IIO_VAL_INT_PLUS_MICRO always. Return the actual value
obtained from the functions. Both functions return IIO_VAL_INT_PLUS_MICRO
upon success.
Signed-off-by: Sachin Kamat <sachin.kamat@xxxxxxxxxxx>
Cc: Srinivas Pandruvada <srinivas.pandruvada@xxxxxxxxxxxxxxx>
---
drivers/iio/pressure/hid-sensor-press.c | 7 ++-----
1 file changed, 2 insertions(+), 5 deletions(-)
diff --git a/drivers/iio/pressure/hid-sensor-press.c b/drivers/iio/pressure/hid-sensor-press.c
index 1cd190c..2c0d2a4 100644
--- a/drivers/iio/pressure/hid-sensor-press.c
+++ b/drivers/iio/pressure/hid-sensor-press.c
@@ -78,7 +78,6 @@ static int press_read_raw(struct iio_dev *indio_dev,
struct press_state *press_state = iio_priv(indio_dev);
int report_id = -1;
u32 address;
- int ret;
int ret_type;
s32 poll_value;
@@ -128,14 +127,12 @@ static int press_read_raw(struct iio_dev *indio_dev,
ret_type = IIO_VAL_INT;
break;
case IIO_CHAN_INFO_SAMP_FREQ:
- ret = hid_sensor_read_samp_freq_value(
+ ret_type = hid_sensor_read_samp_freq_value(
&press_state->common_attributes, val, val2);
- ret_type = IIO_VAL_INT_PLUS_MICRO;
break;
case IIO_CHAN_INFO_HYSTERESIS:
- ret = hid_sensor_read_raw_hyst_value(
+ ret_type = hid_sensor_read_raw_hyst_value(
&press_state->common_attributes, val, val2);
- ret_type = IIO_VAL_INT_PLUS_MICRO;
break;
default:
ret_type = -EINVAL;
--
To unsubscribe from this list: send the line "unsubscribe linux-iio" in
the body of a message to majordomo@xxxxxxxxxxxxxxx