Olof Johansson wrote:
Hi,
With the following patch, my HighPoint 2310 with a Marvell 88SX7042 on
it seems to work OK.
The controller only has 4 ports, with MV_FLAG_DUAL_HC it seems to init 8
ports and fails miserably at probe time. There are no other devices mapped
to that chip, maybe it was just incorrectly specified in the first place?
Signed-off-by: Olof Johansson <olof@xxxxxxxxx>
The docs say 8-port.
Nonetheless, I will apply your patch, since working-in-the-field proof
trumps docs on occasion (including this occasion).
We'll revisit if someone complains that their 7042 only sees 4 of 8 ports.
Jeff
-
To unsubscribe from this list: send the line "unsubscribe linux-ide" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html