On Tue, Feb 27, 2018 at 08:19:00AM +0100, Andrzej Hajda wrote: > HSI2C_MASTER_ST_LOSE state is not documented properly, extensive tests > show that hardware is usually able to recover from this state without > interrupting the transfer. Moreover documentation says that > such state can be caused by slave clock stretching, and should not be > treated as an error during transaction. The only place it indicates > an error is just before starting transaction. In such case bus recovery > procedure should be performed - master should pulse SCL line nine times > and then send STOP condition, it can be repeated until SDA goes high. > The procedure can be performed using manual commands HSI2C_CMD_READ_DATA > and HSI2C_CMD_SEND_STOP. > > Signed-off-by: Andrzej Hajda <a.hajda@xxxxxxxxxxx> Applied to for-next, thanks!
Attachment:
signature.asc
Description: PGP signature