On Thu, Jan 21, 2010 at 06:55:32PM +0100, Valentin Longchamp wrote: > After generating the stop bit by changing MSTA from 1 to 0, > the i2c_imx->stopped was immediatly set to 1. The second test > on i2c_imx->stopped then is correct and the controller never > waits if the bus is busy. This patch corrects this. > > On mx31moboard, stop bit was not generated on single write transfers. > This was kept unnoticed as other transfers are made afterwards that > help the write recipient to resynchronize. > > Thanks to Philippe and Michael for the debugging. > > Signed-off-by: Valentin Longchamp <valentin.longchamp@xxxxxxx> > Signed-off by: Philippe Rétornaz <philippe.retornaz@xxxxxxx> > Reported-by: Michael Bonani <michael.bonani@xxxxxxx> Acked-by: Wolfram Sang <w.sang@xxxxxxxxxxxxxx> -- Pengutronix e.K. | Wolfram Sang | Industrial Linux Solutions | http://www.pengutronix.de/ |