Hi, Manu Abraham schrieb: > Can someone verify whether the STB6100 has component values as in > this image ? http://abraham.manu.googlepages.com/snapshot9.png > in the problematic case ? Am I right that these components are covered by the metal housing near the F connector, so it needs to be removed to have a look at them? > If one is seeing ANALOG CARRIER from what i can see, this is due to a > large Noise Floor, the large noise floor can be caused from phase errors > between the I and Q inputs. This can happen as far as i can guess a > wrong setting in the pump setting. The pump settings are calculated >>from default reference values. If the design has been changed from > the default then there can be issues, based on the explained. I do see ANALOG CARRIER when I switch to the RTL transponder (see attached logfile from an earlier posting). Bye. -- Dipl.-Inform. (FH) Reinhard Nissl mailto:rnissl@xxxxxx _______________________________________________ linux-dvb mailing list linux-dvb@xxxxxxxxxxx http://www.linuxtv.org/cgi-bin/mailman/listinfo/linux-dvb