Re: mesh: Handling application failures on Create/Join/Import

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 12/17, Michał Lowas-Rzechonek wrote:
> I would like to discuss possible solutions to this. 
> 
> One of the ideas is to give the application some time to successfully
> Attach() itself to the new node, otherwise it gets removed.
> 
> Another possibility would be to remove "created but never attached" nodes on
> daemon restart.

Or maybe change the token flow a bit and instead of straight return,
make the daemon call JoinComplete in all 3 cases, expecting a call
return from the application?

If JoinComplete call fails, node could be dropped.

-- 
Michał Lowas-Rzechonek <michal.lowas-rzechonek@xxxxxxxxxxx>