Re: [PATCH v2 2/6] clk: qcom: clk-alpha-pll: Update set_rate for Zonda PLL

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 2.07.2024 5:50 PM, Satya Priya Kakitapalli wrote:
> The Zonda PLL has a 16 bit signed alpha and in the cases where the alpha
> value is greater than 0.5, the L value needs to be adjusted accordingly.
> Thus update the logic for the same.
> 
> Also, fix zonda set_rate failure when PLL is disabled. Currently,
> clk_zonda_pll_set_rate polls for the PLL to lock even if the PLL is
> disabled. However, if the PLL is disabled then LOCK_DET will never
> assert and we'll return an error. There is no reason to poll LOCK_DET
> if the PLL is already disabled, so skip polling in this case.
> 
> Signed-off-by: Satya Priya Kakitapalli <quic_skakitap@xxxxxxxxxxx>
> ---

[...]

> @@ -2077,9 +2089,15 @@ static int clk_zonda_pll_set_rate(struct clk_hw *hw, unsigned long rate,
>  	if (ret < 0)
>  		return ret;
>  
> +	if (a & BIT(15))
> +		zonda_pll_adjust_l_val(rate, prate, &l);

A random check for a seemingly random, undocumented bit only confuses the reader

Konrad