The LLCC block has several banks each with a different base address and holes in between. So it is not a correct approach to cover these banks with a single offset/size. Instead, the individual bank's base address needs to be specified in devicetree with the exact size. On SC7180, there is only one LLCC bank available. So only change needed is to remove the reg-names property from LLCC node to conform to the binding. The driver is expected to parse the reg field based on index to get the addresses of each LLCC banks. Cc: <stable@xxxxxxxxxxxxxxx> # 5.6 Fixes: c831fa299996 ("arm64: dts: qcom: sc7180: Add Last level cache controller node") Reported-by: Parikshit Pareek <quic_ppareek@xxxxxxxxxxx> Signed-off-by: Manivannan Sadhasivam <manivannan.sadhasivam@xxxxxxxxxx> --- arch/arm64/boot/dts/qcom/sc7180.dtsi | 1 - 1 file changed, 1 deletion(-) diff --git a/arch/arm64/boot/dts/qcom/sc7180.dtsi b/arch/arm64/boot/dts/qcom/sc7180.dtsi index f71cf21a8dd8..b0d524bbf051 100644 --- a/arch/arm64/boot/dts/qcom/sc7180.dtsi +++ b/arch/arm64/boot/dts/qcom/sc7180.dtsi @@ -2759,7 +2759,6 @@ dc_noc: interconnect@9160000 { system-cache-controller@9200000 { compatible = "qcom,sc7180-llcc"; reg = <0 0x09200000 0 0x50000>, <0 0x09600000 0 0x50000>; - reg-names = "llcc_base", "llcc_broadcast_base"; interrupts = <GIC_SPI 582 IRQ_TYPE_LEVEL_HIGH>; }; -- 2.25.1