On 18/01/2023 20:16, srinivas pandruvada wrote:
[ ... ]
But we'd better wait for the thermald test result from Srinvias.
A quick test show that things still work with thermald and these
changes.
But I have a question. In some devices trip point temperature is not
static. When hardware changes, we get notification. For example
INT3403_PERF_TRIP_POINT_CHANGED for INT3403 drivers.
Currently get_trip can get the latest changed value. But if we
preregister, we need some mechanism to update them.
When the notification INT3403_PERF_TRIP_POINT_CHANGED happens, we call
int340x_thermal_read_trips() which in turn updates the trip points.
--