Rushan,
In your Quintum go to h323sg and set the
RRQInterval value to something like 60. That would solve your
problem.
Bahram
----- Original Message -----
Sent: Sunday, June 04, 2006 5:13 PM
Subject:
calledPartyNotRegistered
Hi,
I have running openh323gk latest CVS , I have a
problem with register Quintum DX .
I face 1 problem , after
register my quintum to openh323gk all work smooth and I can send calls to
my quintum thru openh323gk after 2 or 3 min . I start getting
calledPartyNotRegistered when I re-register my quintum again and refresh my
quintum registration calls start going thru again.
is there any
option or something in openh323gk to control this issue
?
Regards Rushan