Re: runtime option not working similar for all devices

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 2011-09-13 10:04, Josh Aune wrote:
> 
>>
>> [global]
>> description=Standard Performance test
>> runtime=43200
>> direct=1
>> filename=/dev/sdc
>> numjobs=20
>> group_reporting
> 
> Add time_based and it will run for the full duration specified by runtime.

Yes. With the job given, once fio has done 128kb randreads to any block
on the total size of sdc, it will exit otherwise. If you only give
runtime=xx, then it's just a cap, it wont extend your runtime beyond the
size of the job.

-- 
Jens Axboe

--
To unsubscribe from this list: send the line "unsubscribe fio" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html