Il 14/06/22 18:58, Prashant Malani ha scritto:
On Tue, Jun 14, 2022 at 2:08 AM Pin-yen Lin <treapking@xxxxxxxxxxxx> wrote:
Hi AngeloGioacchino,
On Tue, Jun 14, 2022 at 4:15 PM AngeloGioacchino Del Regno
<angelogioacchino.delregno@xxxxxxxxxxxxx> wrote:
Il 09/06/22 20:09, Prashant Malani ha scritto:
From: Pin-Yen Lin <treapking@xxxxxxxxxxxx>
Add the callback function when the driver receives state
changes of the Type-C port. The callback function configures the
crosspoint switch of the anx7625 bridge chip, which can change the
output pins of the signals according to the port state.
Signed-off-by: Pin-Yen Lin <treapking@xxxxxxxxxxxx>
Signed-off-by: Prashant Malani <pmalani@xxxxxxxxxxxx>
---
Changes since v2:
- No changes.
drivers/gpu/drm/bridge/analogix/anx7625.c | 58 +++++++++++++++++++++++
drivers/gpu/drm/bridge/analogix/anx7625.h | 13 +++++
2 files changed, 71 insertions(+)
diff --git a/drivers/gpu/drm/bridge/analogix/anx7625.c b/drivers/gpu/drm/bridge/analogix/anx7625.c
index d41a21103bd3..2c308d12fab2 100644
--- a/drivers/gpu/drm/bridge/analogix/anx7625.c
+++ b/drivers/gpu/drm/bridge/analogix/anx7625.c
@@ -15,6 +15,7 @@
#include <linux/regulator/consumer.h>
#include <linux/slab.h>
#include <linux/types.h>
+#include <linux/usb/typec_dp.h>
#include <linux/usb/typec_mux.h>
#include <linux/workqueue.h>
@@ -2582,9 +2583,66 @@ static void anx7625_runtime_disable(void *data)
pm_runtime_disable(data);
}
+static void anx7625_set_crosspoint_switch(struct anx7625_data *ctx,
+ enum typec_orientation orientation)
+{
+ if (orientation == TYPEC_ORIENTATION_NORMAL) {
+ anx7625_reg_write(ctx, ctx->i2c.tcpc_client, TCPC_SWITCH_0,
+ SW_SEL1_SSRX_RX1 | SW_SEL1_DPTX0_RX2);
+ anx7625_reg_write(ctx, ctx->i2c.tcpc_client, TCPC_SWITCH_1,
+ SW_SEL2_SSTX_TX1 | SW_SEL2_DPTX1_TX2);
+ } else if (orientation == TYPEC_ORIENTATION_REVERSE) {
+ anx7625_reg_write(ctx, ctx->i2c.tcpc_client, TCPC_SWITCH_0,
+ SW_SEL1_SSRX_RX2 | SW_SEL1_DPTX0_RX1);
+ anx7625_reg_write(ctx, ctx->i2c.tcpc_client, TCPC_SWITCH_1,
+ SW_SEL2_SSTX_TX2 | SW_SEL2_DPTX1_TX1);
+ }
+}
+
+static void anx7625_typec_two_ports_update(struct anx7625_data *ctx)
+{
+ if (ctx->typec_ports[0].dp_connected && ctx->typec_ports[1].dp_connected)
+ /* Both ports available, do nothing to retain the current one. */
+ return;
+ else if (ctx->typec_ports[0].dp_connected)
+ anx7625_set_crosspoint_switch(ctx, TYPEC_ORIENTATION_NORMAL);
+ else if (ctx->typec_ports[1].dp_connected)
+ anx7625_set_crosspoint_switch(ctx, TYPEC_ORIENTATION_REVERSE);
+}
+
static int anx7625_typec_mux_set(struct typec_mux_dev *mux,
struct typec_mux_state *state)
{
+ struct anx7625_port_data *data = typec_mux_get_drvdata(mux);
+ struct anx7625_data *ctx = data->ctx;
+ struct device *dev = &ctx->client->dev;
+
+ bool old_dp_connected = (ctx->typec_ports[0].dp_connected ||
+ ctx->typec_ports[1].dp_connected);
So the old connection state is "either port0 or port1 are currently connected"...
+ bool new_dp_connected;
+
+ if (ctx->num_typec_switches == 1)
+ return 0;
+
+ dev_dbg(dev, "mux_set dp_connected: c0=%d, c1=%d\n",
+ ctx->typec_ports[0].dp_connected, ctx->typec_ports[1].dp_connected);
+
+ data->dp_connected = (state->alt && state->alt->svid == USB_TYPEC_DP_SID &&
+ state->alt->mode == USB_TYPEC_DP_MODE);
+ > + new_dp_connected = (ctx->typec_ports[0].dp_connected ||
+ ctx->typec_ports[1].dp_connected);
...and the new connection state is the same as the old one, because I don't see
anything that could ever modify it in this function's flow, until reaching this
assignment.
The typec mux driver data (`struct anx7625_port_data *data =
typec_mux_get_drvdata(mux)`) is set to one of the
`ctx->typec_ports[*]` in `anx7625_register_mode_switch` (see patch 6
of this series).
So, the `data->dp_connected = ...` assignment may change the new
connection state.
Angelo, I think your interpretation of this logic is not accurate..
|old_dp_connected| represents *whether* port1 or port0 has a DP
partner connected, not that *either* of them has it.
So, this logic looks OK to me.
Hello Prashant,
You're completely right: I've finally seen where this is happening, so yes
we don't know, nor care at that moment, whether data->dp_connected is port0
or port1, we assign and check 'em both again, which is actually smart.
I'm sorry for the misunderstandment - and thank you for your reply.
Feel free to add my
Reviewed-by: AngeloGioacchino Del Regno <angelogioacchino.delregno@xxxxxxxxxxxxx>
Regards,
Angelo