On Wed, May 27, 2020 at 7:50 PM Sam Ravnborg <sam@xxxxxxxxxxxx> wrote: > On Wed, May 27, 2020 at 05:47:21PM +0200, Arnd Bergmann wrote: > > On Wed, May 27, 2020 at 4:52 PM Sam Ravnborg <sam@xxxxxxxxxxxx> wrote: > > > > > > Hi Arnd. > > > > > > On Wed, May 27, 2020 at 03:31:42PM +0200, Arnd Bergmann wrote: > > > > The vexpress_config code fails to link in some configurations: > > > > > > > > drivers/gpu/drm/pl111/pl111_versatile.o: in function `pl111_versatile_init': > > > > (.text+0x1f0): undefined reference to `devm_regmap_init_vexpress_config' > > > > > > > > Add a dependency that links to this only if the dependency is there, > > > > and prevent the configuration where the drm driver is built-in but > > > > the config is a loadable module. > > > > > > > > Fixes: 826fc86b5903 ("drm: pl111: Move VExpress setup into versatile init") > > > > Signed-off-by: Arnd Bergmann <arnd@xxxxxxxx> > > > > > > Could this be another way to fix it: > > > > > > diff --git a/drivers/gpu/drm/pl111/pl111_versatile.c b/drivers/gpu/drm/pl111/pl111_versatile.c > > > index 64f01a4e6767..1c38d3bd2e84 100644 > > > --- a/drivers/gpu/drm/pl111/pl111_versatile.c > > > +++ b/drivers/gpu/drm/pl111/pl111_versatile.c > > > @@ -379,7 +379,7 @@ static int pl111_vexpress_clcd_init(struct device *dev, struct device_node *np, > > > u32 val; > > > int ret; > > > > > > - if (!IS_ENABLED(CONFIG_VEXPRESS_CONFIG)) > > > + if (!IS_REACHABLE(CONFIG_VEXPRESS_CONFIG)) > > > return -ENODEV; > > > > > > /* > > > > > > > > > Then we no longer have the whole driver depending on > > > the value of VEXPRESS_CONFIG. > > > Not that I like IS_REACHABLE() but we already had > > > IS_ENABLED() to cover up here, and that was not enough. > > > > > > With your patch would we then need the IS_ENABLED() > > > check? > > > > The IS_ENABLED() check is what I'm adding, not removing. I'd still > > the Kconfig dependency combined with that check over > > IS_REACHABLE(), which is more likely to silently not work. > > Then the now redundant IS_ENABLED() check should go. > With you patch it looks like this: > > ... > if (IS_ENABLED(CONFIG_VEXPRESS_CONFIG) && ...) > pl111_vexpress_clcd_init() > > > And in pl111_vexpress_clcd_init() we have: > > { > if (!IS_ENABLED(CONFIG_VEXPRESS_CONFIG)) > return -ENODEV; > > The IS_ENABLED() in pl111_vexpress_clcd_init() is redundant > and the patch should drop it. Ah I see your point now, sorry I missed the double IS_ENABLED() check at first. I'll remove the second one from my patch and resubmit after some more build testing then. Arnd _______________________________________________ dri-devel mailing list dri-devel@xxxxxxxxxxxxxxxxxxxxx https://lists.freedesktop.org/mailman/listinfo/dri-devel