The cooling-{min,max}-level properties are marked as optional in Documentation/devicetree/bindings/cpufreq/cpufreq-dt.txt and the usage in various device tree matches this, i.e., some cooling device in the device trees provide these properties while others do not. Make the bindings in Documentation/devicetree/bindings/thermal/thermal.txt consistent with the cpufreq-dt bindings by marking the cooling-*-level properties as optional. Signed-off-by: Punit Agrawal <punit.agrawal@xxxxxxx> Cc: Eduardo Valentin <edubezval@xxxxxxxxx> Cc: Rob Herring <robh+dt@xxxxxxxxxx> Cc: Mark Rutland <mark.rutland@xxxxxxx> Cc: Ian Campbell <ijc+devicetree@xxxxxxxxxxxxxx> Cc: Kumar Gala <galak@xxxxxxxxxxxxxx> --- Documentation/devicetree/bindings/thermal/thermal.txt | 17 +++++++++-------- 1 file changed, 9 insertions(+), 8 deletions(-) diff --git a/Documentation/devicetree/bindings/thermal/thermal.txt b/Documentation/devicetree/bindings/thermal/thermal.txt index 8320186..41b817f 100644 --- a/Documentation/devicetree/bindings/thermal/thermal.txt +++ b/Documentation/devicetree/bindings/thermal/thermal.txt @@ -60,14 +60,6 @@ properties) should be defined in a particular device's binding. For more examples of cooling devices, refer to the example sections below. Required properties: -- cooling-min-level: An integer indicating the smallest - Type: unsigned cooling state accepted. Typically 0. - Size: one cell - -- cooling-max-level: An integer indicating the largest - Type: unsigned cooling state accepted. - Size: one cell - - #cooling-cells: Used to provide cooling device specific information Type: unsigned while referring to it. Must be at least 2, in order Size: one cell to specify minimum and maximum cooling state used @@ -77,6 +69,15 @@ Required properties: See Cooling device maps section below for more details on how consumers refer to cooling devices. +Optional properties: +- cooling-min-level: An integer indicating the smallest + Type: unsigned cooling state accepted. Typically 0. + Size: one cell + +- cooling-max-level: An integer indicating the largest + Type: unsigned cooling state accepted. + Size: one cell + * Trip points The trip node is a node to describe a point in the temperature domain -- 2.5.0 -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html