On Wed, Dec 04, 2024 at 06:24:47PM +0000, Lothar Rubusch wrote: > Add interrupt-names INT1 and INT2 for the two interrupt lines of the > sensor. Only one line will be connected for incoming events. The driver > needs to be configured accordingly. If no interrupt line is set up, the > sensor will still measure, but no events are possible. > > Signed-off-by: Lothar Rubusch <l.rubusch@xxxxxxxxx> > --- > .../devicetree/bindings/iio/accel/adi,adxl345.yaml | 11 +++++++++++ > 1 file changed, 11 insertions(+) > > diff --git a/Documentation/devicetree/bindings/iio/accel/adi,adxl345.yaml b/Documentation/devicetree/bindings/iio/accel/adi,adxl345.yaml > index 280ed479ef5..a4c2cefe1a4 100644 > --- a/Documentation/devicetree/bindings/iio/accel/adi,adxl345.yaml > +++ b/Documentation/devicetree/bindings/iio/accel/adi,adxl345.yaml > @@ -37,6 +37,15 @@ properties: > interrupts: > maxItems: 1 > > + interrupt-names: > + description: Use either INT1 or INT2 for events, or ignore events. > + minItems: 1 > + maxItems: 2 No improvements, no responses and according to commit msg you have only one item, so instead above and below just: description: ......... items: - enum: [ int1, int2] Best regards, Krzysztof