On Tue, Nov 12, 2024 at 07:01:06PM +0200, Matti Vaittinen wrote: > The sense resistor used for measuring currents is typically some tens of > milli Ohms. It has accidentally been documented to be tens of mega Ohms. > Fix the size of this resistor and a few copy-paste errors while at it. > > Drop the unsuitable 'rohm,charger-sense-resistor-ohms' property (which > can't represent resistors smaller than one Ohm), and introduce a new > 'rohm,charger-sense-resistor-micro-ohms' property with appropriate > minimum, maximum and default values instead. > > Fixes: 4238dc1e6490 ("dt_bindings: mfd: Add ROHM BD71815 PMIC") > Signed-off-by: Matti Vaittinen <mazziesaccount@xxxxxxxxx> Acked-by: Conor Dooley <conor.dooley@xxxxxxxxxxxxx>