Re: [PATCH 2/6] dt-bindings: PCI: mediatek-gen3: Allow exact number of clocks only

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 25/09/2024 12:57, Fei Shao wrote:
> In MediaTek PCIe gen3 bindings, "clocks" accepts a range of 1-6 clocks
> across all SoCs. But in practice, each SoC requires a particular number
> of clocks as defined in "clock-names", and the length of "clocks" and
> "clock-names" can be inconsistent with current bindings.
> 
> For example:
> - MT8188, MT8192 and MT8195 all require 6 clocks, while the bindings
>   accept 4-6 clocks.
> - MT7986 requires 4 clocks, while the bindings accept 4-6 clocks.
> 
> Update minItems and maxItems properties for individual SoCs as needed to
> only accept the correct number of clocks.
> 


Reviewed-by: Krzysztof Kozlowski <krzk@xxxxxxxxxx>

Best regards,
Krzysztof





[Index of Archives]     [Device Tree Compilter]     [Device Tree Spec]     [Linux Driver Backports]     [Video for Linux]     [Linux USB Devel]     [Linux PCI Devel]     [Linux Audio Users]     [Linux Kernel]     [Linux SCSI]     [XFree86]     [Yosemite Backpacking]


  Powered by Linux