On 25/09/2024 12:57, Fei Shao wrote: > In MediaTek PCIe gen3 bindings, "clocks" accepts a range of 1-6 clocks > across all SoCs. But in practice, each SoC requires a particular number > of clocks as defined in "clock-names", and the length of "clocks" and > "clock-names" can be inconsistent with current bindings. > > For example: > - MT8188, MT8192 and MT8195 all require 6 clocks, while the bindings > accept 4-6 clocks. > - MT7986 requires 4 clocks, while the bindings accept 4-6 clocks. > > Update minItems and maxItems properties for individual SoCs as needed to > only accept the correct number of clocks. > Reviewed-by: Krzysztof Kozlowski <krzk@xxxxxxxxxx> Best regards, Krzysztof