Change order of properties in order for the end user to de-prioritize pmin-pascal and pmax-pascal which are superseded by pressure-triplet. Add pressure-triplet property which automatically initializes pmin-pascal and pmax-pascal inside the driver Rework honeywell,pmXX-pascal requirements based on feedback from Jonathan and Conor. Signed-off-by: Petre Rodan <petre.rodan@xxxxxxxxxxxxxxx> Signed-off-by: Andreas Klinger <ak@xxxxxxxxxxxxx> --- .../iio/pressure/honeywell,mprls0025pa.yaml | 64 ++++++++++++++----- 1 file changed, 47 insertions(+), 17 deletions(-) diff --git a/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml b/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml index 84ced4e5a7da..e4021306d187 100644 --- a/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml +++ b/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml @@ -19,14 +19,17 @@ description: | calls them "mpr series". All of them have the identical programming model and differ in the pressure range, unit and transfer function. - To support different models one need to specify the pressure range as well as - the transfer function. Pressure range needs to be converted from its unit to + To support different models one need to specify its pressure triplet as well + as the transfer function. + + For custom models the pressure values can alternatively be specified manually. + The minimal range value stands for the minimum pressure and the maximum value + also for the maximum pressure with linear relation inside the range. + Pressure range needs to be converted from the datasheet specified unit to pascal. The transfer function defines the ranges of numerical values delivered by the - sensor. The minimal range value stands for the minimum pressure and the - maximum value also for the maximum pressure with linear relation inside the - range. + sensor. Specifications about the devices can be found at: https://prod-edam.honeywell.com/content/dam/honeywell-edam/sps/siot/en-us/ @@ -54,14 +57,6 @@ properties: If not present the device is not reset during the probe. maxItems: 1 - honeywell,pmin-pascal: - description: - Minimum pressure value the sensor can measure in pascal. - - honeywell,pmax-pascal: - description: - Maximum pressure value the sensor can measure in pascal. - honeywell,transfer-function: description: | Transfer function which defines the range of valid values delivered by the @@ -72,17 +67,52 @@ properties: enum: [1, 2, 3] $ref: /schemas/types.yaml#/definitions/uint32 + honeywell,pressure-triplet: + description: | + Case-sensitive five character string that defines pressure range, unit + and type as part of the device nomenclature. In the unlikely case of a + custom chip, unset and provide pmin-pascal and pmax-pascal instead. + enum: [0001BA, 01.6BA, 02.5BA, 0060MG, 0100MG, 0160MG, 0250MG, 0400MG, + 0600MG, 0001BG, 01.6BG, 02.5BG, 0100KA, 0160KA, 0250KA, 0006KG, + 0010KG, 0016KG, 0025KG, 0040KG, 0060KG, 0100KG, 0160KG, 0250KG, + 0015PA, 0025PA, 0030PA, 0001PG, 0005PG, 0015PG, 0030PG, 0300YG] + $ref: /schemas/types.yaml#/definitions/string + + honeywell,pmin-pascal: + description: + Minimum pressure value the sensor can measure in pascal. + To be specified only if honeywell,pressure-triplet is not set. + + honeywell,pmax-pascal: + description: + Maximum pressure value the sensor can measure in pascal. + To be specified only if honeywell,pressure-triplet is not set. + vdd-supply: description: provide VDD power to the sensor. required: - compatible - reg - - honeywell,pmin-pascal - - honeywell,pmax-pascal - honeywell,transfer-function - vdd-supply +oneOf: + - required: + - honeywell,pmin-pascal + - honeywell,pmax-pascal + - required: + - honeywell,pressure-triplet + +allOf: + - if: + required: + - honeywell,pressure-triplet + then: + properties: + honeywell,pmin-pascal: false + honeywell,pmax-pascal: false + additionalProperties: false examples: @@ -99,8 +129,8 @@ examples: reset-gpios = <&gpio3 19 GPIO_ACTIVE_HIGH>; interrupt-parent = <&gpio3>; interrupts = <21 IRQ_TYPE_EDGE_RISING>; - honeywell,pmin-pascal = <0>; - honeywell,pmax-pascal = <172369>; + + honeywell,pressure-triplet = "0025PA"; honeywell,transfer-function = <1>; vdd-supply = <&vcc_3v3>; }; -- 2.41.0