Hi Adam, thanks for the update. Am Sonntag, 22. Oktober 2023, 18:19:10 CEST schrieb Adam Ford: > The NPU is based on the Vivante GC8000 and its power-domain > is controlled my pgc_mlmix. Since the power-domain uses > some of these clocks, setup the clock parent and rates > inside the power-domain, and add the NPU node. > > The data sheet states the CLK_ML_AHB should be 300MHz for > nominal, but 800MHz clock will divide down to 266 instead. > Boards which operate in over-drive mode should update the > clocks on their boards accordingly. When the driver loads, > the NPU numerates as: > > etnaviv-gpu 38500000.npu: model: GC8000, revision: 8002 There seems to be some race condition upon GPU/NPU detection. Sometimes I get these messages: [ 1.338100] etnaviv-gpu 38000000.gpu: model: GC7000, revision: 6204 [ 1.344469] etnaviv-gpu 38008000.gpu: model: GC520, revision: 5341 [ 1.350748] etnaviv-gpu 38500000.npu: model: GC0, revision: 0 [ 1.356514] etnaviv-gpu 38500000.npu: Unknown GPU model Sometimes I see GC8000 being detected as you have written. Despite that the patch itself looks good. Reviewed-by: Alexander Stein <alexander.stein@xxxxxxxxxxxxxxx> > > Signed-off-by: Adam Ford <aford173@xxxxxxxxx> > --- > > V2: Move the clock parent and rate assignments to the ppc_mlmix node > since clock parents should be configured before they are used, > and pgc_mlmix uses them first. > Slow the clock rates down to confirm to nominal mode instead of > overdrive mode. > > diff --git a/arch/arm64/boot/dts/freescale/imx8mp.dtsi > b/arch/arm64/boot/dts/freescale/imx8mp.dtsi index > c9a610ba4836..a18b9ba98ea2 100644 > --- a/arch/arm64/boot/dts/freescale/imx8mp.dtsi > +++ b/arch/arm64/boot/dts/freescale/imx8mp.dtsi > @@ -887,6 +887,15 @@ pgc_mlmix: power-domain@24 { > clocks = <&clk IMX8MP_CLK_ML_AXI>, > <&clk IMX8MP_CLK_ML_AHB>, > <&clk IMX8MP_CLK_NPU_ROOT>; > + assigned-clocks = <&clk IMX8MP_CLK_ML_CORE>, > + <&clk IMX8MP_CLK_ML_AXI>, > + <&clk IMX8MP_CLK_ML_AHB>; > + assigned-clock- parents = <&clk IMX8MP_SYS_PLL1_800M>, > + <&clk IMX8MP_SYS_PLL1_800M>, > + <&clk IMX8MP_SYS_PLL1_800M>; > + assigned-clock- rates = <800000000>, > + <800000000>, > + <300000000>; > }; > }; > }; > @@ -2012,6 +2021,18 @@ vpumix_blk_ctrl: blk-ctrl@38330000 { > interconnect-names = "g1", "g2", "vc8000e"; > }; > > + npu: npu@38500000 { > + compatible = "vivante,gc"; > + reg = <0x38500000 0x200000>; > + interrupts = <GIC_SPI 13 IRQ_TYPE_LEVEL_HIGH>; > + clocks = <&clk IMX8MP_CLK_NPU_ROOT>, > + <&clk IMX8MP_CLK_NPU_ROOT>, > + <&clk IMX8MP_CLK_ML_AXI>, > + <&clk IMX8MP_CLK_ML_AHB>; > + clock-names = "core", "shader", "bus", "reg"; > + power-domains = <&pgc_mlmix>; > + }; > + > gic: interrupt-controller@38800000 { > compatible = "arm,gic-v3"; > reg = <0x38800000 0x10000>, -- TQ-Systems GmbH | Mühlstraße 2, Gut Delling | 82229 Seefeld, Germany Amtsgericht München, HRB 105018 Geschäftsführer: Detlef Schneider, Rüdiger Stahl, Stefan Schneider http://www.tq-group.com/