Although this property is used right now for IIO_CHAN_INFO_SCALE, this ADC has two internal reference voltages, which the driver currently doesn't make use of. Fixes: db73419d8c06 ("dt-bindings: iio: adc: Add binding documentation for NXP IMX8QXP ADC") Signed-off-by: Alexander Stein <alexander.stein@xxxxxxxxxxxxxxx> --- Thanks for your inputs. This improved descritpion should make it clear that this property is only about the external reference voltage, not about the optional, internal voltages. Changes in v2: * Improved commit message subject as suggested * Add hint about feature flag regarding multiple, internal, reference voltages .../devicetree/bindings/iio/adc/nxp,imx8qxp-adc.yaml | 7 +++++++ 1 file changed, 7 insertions(+) diff --git a/Documentation/devicetree/bindings/iio/adc/nxp,imx8qxp-adc.yaml b/Documentation/devicetree/bindings/iio/adc/nxp,imx8qxp-adc.yaml index 63369ba388e4..878e67054d7c 100644 --- a/Documentation/devicetree/bindings/iio/adc/nxp,imx8qxp-adc.yaml +++ b/Documentation/devicetree/bindings/iio/adc/nxp,imx8qxp-adc.yaml @@ -39,6 +39,12 @@ properties: power-domains: maxItems: 1 + vref-supply: + description: | + External ADC reference voltage supply on VREFH pad. If VERID[MVI] is + set, there are additional, internal reference voltages selectable. + VREFH1 is always from VREFH pad. + "#io-channel-cells": const: 1 @@ -72,6 +78,7 @@ examples: assigned-clocks = <&clk IMX_SC_R_ADC_0>; assigned-clock-rates = <24000000>; power-domains = <&pd IMX_SC_R_ADC_0>; + vref-supply = <®_1v8>; #io-channel-cells = <1>; }; }; -- 2.34.1