On 22/03/2023 06:56, Zeynep Arslanbenzer wrote: > Add ADI MAX77658 power supply devicetree document. > > Signed-off-by: Nurettin Bolucu <Nurettin.Bolucu@xxxxxxxxxx> > Signed-off-by: Zeynep Arslanbenzer <Zeynep.Arslanbenzer@xxxxxxxxxx> > --- > .../power/supply/adi,max77658-battery.yaml | 58 +++++++++++++++++++ > 1 file changed, 58 insertions(+) > create mode 100644 Documentation/devicetree/bindings/power/supply/adi,max77658-battery.yaml > > diff --git a/Documentation/devicetree/bindings/power/supply/adi,max77658-battery.yaml b/Documentation/devicetree/bindings/power/supply/adi,max77658-battery.yaml > new file mode 100644 > index 000000000000..0b696f7c4d1b > --- /dev/null > +++ b/Documentation/devicetree/bindings/power/supply/adi,max77658-battery.yaml > @@ -0,0 +1,58 @@ > +# SPDX-License-Identifier: GPL-2.0-only OR BSD-2-Clause > +%YAML 1.2 > +--- > +$id: http://devicetree.org/schemas/power/supply/adi,max77658-battery.yaml# > +$schema: http://devicetree.org/meta-schemas/core.yaml# > + > +title: Battery for MAX77658 PMIC from ADI. Implement all previous comments, not just some. > + > +maintainers: > + - Nurettin Bolucu <Nurettin.Bolucu@xxxxxxxxxx> > + - Zeynep Arslanbenzer <Zeynep.Arslanbenzer@xxxxxxxxxx> > + > +description: | > + This module is part of the MAX77658 MFD device. For more details > + see Documentation/devicetree/bindings/mfd/adi,max77658.yaml. > + > + The fuel gauge is represented as a sub-node of the PMIC node on the device tree. > + > +properties: > + compatible: > + const: > + adi,max77658-battery It's one line. > + > + reg: > + maxItems: 1 > + > + adi,valrt-min-microvolt: > + description: Minimum voltage value that triggers the alarm. > + > + adi,valrt-max-microvolt: > + description: Maximum voltage value that triggers the alarm. Use the same syntax as battery.yaml > + > + adi,salrt-min-percent: > + description: Minimum percentage of battery that triggers the alarm. > + > + adi,salrt-max-percent: > + description: Maximum percentage of battery that triggers the alarm. That's not suitable for DT. Do not encode policies into DT. > + > + adi,ialrt-min-microamp: > + description: Minimum current value that triggers the alarm. > + > + adi,ialrt-max-microamp: > + description: Maximum current value that triggers the alarm. > + > + monitored-battery: > + description: > > + phandle to a "simple-battery" compatible node. > + > + This property must be a phandle to a node using the format described You already said it above. > + in battery.yaml, with the following properties being required: > + - alert-celsius > + > +required: > + - compatible Why reg and monitored-batter are not required? Best regards, Krzysztof