power-supply properties are reported in µV, µA and µW. The IIO API provides mV, mA, mW, so the values need to be multiplied by 1000. Signed-off-by: Sebastian Reichel <sre@xxxxxxxxxx> --- drivers/power/supply/generic-adc-battery.c | 3 +++ 1 file changed, 3 insertions(+) diff --git a/drivers/power/supply/generic-adc-battery.c b/drivers/power/supply/generic-adc-battery.c index 917bd2a6cc52..535972a332b3 100644 --- a/drivers/power/supply/generic-adc-battery.c +++ b/drivers/power/supply/generic-adc-battery.c @@ -136,6 +136,9 @@ static int read_channel(struct gab *adc_bat, enum power_supply_property psp, result); if (ret < 0) pr_err("read channel error\n"); + else + *result *= 1000; + return ret; } -- 2.39.2